Applied for :In vivo/In utero/Ex utero/In ovo/Ex ovo/Ex vivo
CUY21EDIT(Electroporator) can introduce DNAs, siRNAs, drugs, into the sample like in vivo, in utero, ex utero, in ovo, ex ovo, ex vivo and etc. Our many kinds of electrodes can fit any experiments you are focusing on.
CUY21EDIT has a lot of performance in CUY21 series machines
■in vivo Electroporator CUY21EDIT (BEX Co., Ltd.)■
・In vivo electroporation | |
DC wave:Square |
BEX CO., LTD. manufactures CUY21 series machines.
Please ask us through the form below about the quotation, demonstration, and etc.
BEX's CUY21 series machines can transfect to the sample you are focusing on. Moreover, our many kinds of electrodes can fit every expriment you are doing.
method | species | target |
---|---|---|
In vivo electroporation (CUY21) | Adult mouse | skin, muscle, kidney, liver, spleen, vessel, bladder, testis, ovary, brain, brown adipose tissue, fertile egg |
Adult rat | muscle | |
newborn mouse / rat | brain, retina, cornea | |
hamster | muscle | |
rabbit | muscle, knee joint | |
zebrafish | tail fin, retina | |
Xenopus | embryo, retina(tadpole) | |
Gryllus bimaculatus | embryo | |
honey bee | brain | |
parastic insect(blood fluke) | whole body | |
In utero electroporation (CUY21) | mouse embryo | brain, spinal cord, retina, inner ear |
rat embryo | brain | |
Ex utero electroporation (CUY21) | mouse embryo | brain |
mouse / rat embryo | whole embryo culture (brain vesicle, neural tube) | |
In ovo electroporation (CUY21) | chicken embryo | neural tube, eye vesicle, limb bud (limb bud), arthromere(limb bud), programmed heart region(limb bud), posterior mesoderm, programmed trachea-bronchi region, early blastoderm |
quail embryo | neural tube | |
Ex ovo electroporation (CUY21) | chicken early embryo | New’s culture |
chicken embryo | liver, cerebellum | |
Ex vivo electroporation (CUY21) | mouse | brain, retina, small intestine, tooth germ, inner ear |
rat | brain | |
chicken embryo | spinal cord, brain stem, retina, anterior stomach | |
Single Cell electroporation(CUY21) | single cell | adherant animal cells |
single cell | plant protoplast | |
Click for the electrodes for CUY21 series machines !
Click for the references of CUY21 series machines !
measures impedance between electrodes before and after pulse generation. Impedance measured beforehand reveals the current value through Ohm's law. That means the condition of voltage can be reset for the better one. Moreover, the impedance measurement plays an important role to concern the accuracy of the experiments (whether the present condition corresponds to the last one or not). CUY21Vivo-SQ provides you reproducibility provides the best applications which fit various samples. Fine move of electrodes adjusts the impedance between electrodes.
CUY21EDIT (electroporator) is calibrated below 100V. This results in the generation of the high accurate voltage, especially around 50V, which is used for in vivo electroporation.This is why the voltage error which has a influence on electroporation is ignored.
CUY21EDIT(electroporator) automatically measures and monitors the effective current and voltage. CUY21EDIT provides information whether the experiment is successful or not before the observation of the experiment result. That means you can save your time and money.
The voltage range of CUY21EDIT(electroporator) is 0~500V. CUY21EDIT fits any expriments.
CUY21EDIT(electroporator) has a large LCD touch panel. The setting is carried out on the touch panel. The values of the settings, effective voltage and current, etc are displayed on the touch panel.
If you accidentaly touch the electrode during the electroporation, you will be hurt or burned. CUY21EDIT avoid an accident like this. If the high current runs, the limitter in CUY21EDIT automatically works and stops the electroporation program immediately. CUY21EDIT is designated for the user-kind.
DC Wave | Square |
---|---|
Voltage | 1~500V(by the 1V) |
Pulse time | 0.1~999.9ms(by the 0.1ms) |
Pulse Interval | 0.1~999.9ms(by the 0.1ms) |
Pulse number | 1~99 time(s) |
Impedance measurement | ~18kΩ |
Effective voltage | 1~500V |
Effective current | 0.01~4.00A |
Memory track | 2 tracks |
Power | Single phase 100V,5A,50/60Hz |
Size | W390cm×L450cm×H250cm |
*This product might change its specification and/or outline because of the improvement without a notice.
We are always welcoming the demonstraiton for CUY21(electroporator). Please fill out the form below and let us know your request and needs !!
We accept the maintenance and/or repair for Electroporator CUY21,CUY21EDIT,CUY21Vivo-SQ,CUY21EX,CUY21Vitro-EX、Cell fusion unit LF101,LF301、Electrodes、any other accessary. Our staff will contact you immediately !! Please fill out the form below and let us know your request and needs !!
CUY21Vivo-SQ(In vivo electroporator)
CUY21EDIT(In vivo electroporator)