Applied for :In vivo/In utero/Ex utero/In ovo/Ex ovo/Ex vivo/adhesive cells
CUY21EX(electroporator) is a next-generation electroporator with the dual pulse waves and attenuating pulse(exponencial square) which lead less damage to the samples and higher efficiency to ntroduce DNAs, siRNAs, drugs, etc. Our many kinds of electrodes can fit any experiments you are focusing on.
Moreover, our special electrodes for the adherent cells can carry out the highly efficient electroporation with the cells on the plate (means without removal out of the plate using reagents like trypsin.
■Electroporator CUY21EX (BEX Co., Ltd.)■
Manufactured by BEX CO.,LTD. | |
■Dual pulse electroporation■ |
BEX CO., LTD. manufactures CUY21 series machines.
Please ask us through the form below about the quotation, demonstration, and etc.
BEX's CUY21 series machines can transfect to the sample you are focusing on. Moreover, our many kinds of electrodes can fit every expriment you are doing.
method | species | target |
---|---|---|
In vivo electroporation (CUY21) | Adult mouse | skin, muscle, kidney, liver, spleen, vessel, bladder, testis, ovary, brain, brown adipose tissue, fertile egg |
Adult rat | muscle | |
newborn mouse / rat | brain, retina, cornea | |
hamster | muscle | |
rabbit | muscle, knee joint | |
zebrafish | tail fin, retina | |
Xenopus | embryo, retina(tadpole) | |
Gryllus bimaculatus | embryo | |
honey bee | brain | |
parastic insect(blood fluke) | whole body | |
In utero electroporation (CUY21) | mouse embryo | brain, spinal cord, retina, inner ear |
rat embryo | brain | |
Ex utero electroporation (CUY21) | mouse embryo | brain |
mouse / rat embryo | whole embryo culture (brain vesicle, neural tube) | |
In ovo electroporation (CUY21) | chicken embryo | neural tube, eye vesicle, limb bud (limb bud), arthromere(limb bud), programmed heart region(limb bud), posterior mesoderm, programmed trachea-bronchi region, early blastoderm |
quail embryo | neural tube | |
Ex ovo electroporation (CUY21) | chicken early embryo | New’s culture |
chicken embryo | liver, cerebellum | |
Ex vivo electroporation (CUY21) | mouse | brain, retina, small intestine, tooth germ, inner ear |
rat | brain | |
chicken embryo | spinal cord, brain stem, retina, anterior stomach | |
Single Cell electroporation(CUY21) | single cell | adherant animal cells |
single cell | plant protoplast | |
Click for the electrodes for CUY21 series machines !
Click for the references of CUY21 series machines !
CUY21 Vitro-EX has a hybrid system of high-voltage pulse, "Poration Pulse" and low-voltage pulse, "Driving Pulse. High voltaged Poration Pulse in short time pierces the cell surface. Afterward, repeat of low voltaged Driving Pulses electrophoreses target DNA or drug into the inside of the cell. High transfection and viability are expected with the best condition suitable for the cells because you can adjust the time and intervals of the pulses as you like.
CUY21EX can generates >=500V voltage and beeps to warn you about the danger before and during the pulse generation. CUY21EX fits electroporation for suspended aminal or plant cells and for adherant cells on the plate or dish without the cells pealed off, moreover, for the research of iPS cells.
CUY21EX measures impedance between electrodes before and after pulse generation. Impedance measured beforehand reveals the current value through Ohm's law. That means the condition of voltage can be reset for the better one. Moreover, the impedance measurement plays an important role to concern the accuracy of the experiments (whether the present condition corresponds to the last one or not). CUY21EX provides you reproducibility provides the best applications which fit various samples. Fine move of electrodes adjusts the impedance between electrodes.
CUY21EX automatically measures and monitors the effective current and voltage. Your experiment is carried out more smoothly as a result of obtaining the accurate value of current and voltage.
CUY21EX has the user-kind interface with the LED display to show you the settings and measured value on respectively. The numeric keypad helps more.has the user-kind interface with the LED display to show you the settings and measured value on respectively. The numeric keypad helps more.
CUY21EX has 99 tracks for the memory of your programs.
Poration pulse voltage | 1~500V (by the 1V) |
---|---|
Poration pulse time | 0.01~99.9ms (by the 0.01ms) |
Poration pulse interval | 0.05~99.9ms(by the 0.01ms) |
Driving pulse voltage | 1~500V (by the 1V) |
Driving pulse time | 0.1~99.9ms (by the 0.1ms) |
Driving pulse interval | 1~999ms (by the 1ms) |
Pulse number | 1~10 time(s) |
DC Wave | exponencial square |
Impedance Measurement | ~30kΩ |
Effective Voltage | 1~500V |
Effective Current:1~500V | 0.1~50A |
Memory track | 99 tracks |
Power | Single phase 100V,5A,50/60Hz |
Size | W360cm×L380cm×H180cm |
*This product might change its specification and/or outline because of the improvement without a notice.
We are always welcoming the demonstraiton for CUY21(electroporator). Please fill out the form below and let us know your request and needs !!
We accept the maintenance and/or repair for Electroporator CUY21,CUY21EDIT,CUY21Vivo-SQ,CUY21EX,CUY21Vitro-EX、Cell fusion unit LF101,LF301、Electrodes、any other accessary. Our staff will contact you immediately !! Please fill out the form below and let us know your request and needs !!
CUY21Vivo-SQ(In vivo electroporator)