・Service for cloning and sequencing unknown sequence area by use of Straight Walk® Kit (Right Walk® kit, previously)
・An unknown region is cloned from the sample ten times as a large genome size as human.
・The adaptor is added to the gene after the restriction enzyme treatment. PCR is conducted with the primer designated for the known sequence. It is possible to subclone to various vectors by adding suitable restriction enzyme sites to known primers because the sequence of the primer includes the cutting site for NotⅠ.
・At most, 9 kinds of restriction enzymes are used for analysis.
Patent
NEW OLIGONUCLEOTIDE ADAPTOR AND PRIMER (JP,4603798,B)
①Restriction enzyme tretment
(The numbe of kinds o frestriction enzyme depends on the location for restriction enzyme sites. )
②1 base elongation
③Adaptor binding
④First PCR
⑤Second PCR(nested RCR)
(The size of PCR products depends on the location for the restriction enzyme sites although Max. 5kb products is able to be obtained threorically.)
⑥cloning
(Cloning the biggest PCR products from ones obtained in ⑤)
⑦Sequencing
Reference for Straight Walk®Kit (Right Walk®Kit)
Straight Walk:A modified method of ligation-mediated genome walking for plant species with large genomes
Analytical Biochemistry 388(2009) 158-160
Tokuji Tsuchiya, Nanako Kameya, Ikuo Nakamura
De novo DNA methylation of the 35S enhancer revealed by high-resolution methylation analysis of an entire T-DNA segment in transgenic gentian
Plant Biotechnology 28,223-230(2011)
Satoshi Yamasaki, Masayuki Oda, Nozomu Koizumi, Kazuhiko Mitsukuri, Masafumi Johkan, Takashi Nakatsuka, Masahiro Nishihara, Kei-ichiro Mishiba
Novel Isoforms of Heat Shock Transcription Factor 1 Are Induced by Hypoxia in the Pacific Oyster Crassostrea gigas
J.Exp.Zool. 315:394-407,2011
SHINYA KAWABE AND YOSHIHIRO YOKOYAMA
Price | Delivery | |
---|---|---|
Cloning from one side※1 | ¥90,000 | About 3 weeks ~ |
Cloning from both sides※2 | ¥160,000 | About 4 weeks ~ |
※1 Sequencing the unknown area in either 5' end upstream or 3' end downstream in the known area.
※2 Sequencing the unknown area in both 5' end upstream and 3' end downstream
>>For the kit of "Straight Walk® Kit" for you to do on yourself
1.Please send the order form and text file of the known sequence data to us by email
・known sequence information
2.Please send the sample and document described below to us:
・Order form
・Genome DNA (> 2μg) ※Please keep the sample chilled during delivery.
BEX Co., Ltd.
4th Floor, 2-61-15 Itabashi, Itabashiku-ku Tokyo 173-0004 Japan
TEL. 03-5375-1071
Unknown sequence (text-fomatted)
Operation Report
・The actual fee is payable in the unavoidable termination after the discussion with the customer
・The sample is adequately discarded under the strict security, law, regulation, and rules.
・The freight of the sample to BEX is payable.
Certification of Cell Line(STR)
Genotyping (T-RFLP, SSR, etc.)
Sequence Detection by Straight Walk®
| Site Map | Privacy Policy |